The Dredger clot retrieval stroke is an interventional treatment used in the treatment of stroke patients. A stroke is a medical condition caused by interruption of blood supply to the brain, usually caused by a blood clot or embolus getting stuck in a brain.
The Dredger clot retrieval stroke is an interventional treatment used in the treatment of stroke patients. A stroke is a medical condition caused by interruption of blood supply to the brain, usually caused by a blood clot or embolus getting stuck in a brain artery. The purpose of Dredger clot retrieval stroke is to restore blood flow and function to the brain by removing a blood clot or embolus. This treatment uses a device that is inserted into an artery and then through a catheter into a blood vessel in the brain. A clot retrieval device on the catheter grabs and pulls the blood clot, or embolus, and removes it from a blood vessel in the brain. The advantage of clot retrieval stroke is that blood flow can be restored in a shorter time to reduce the risk of brain damage. It can also effectively reduce the mortality and disability rate of patients. In addition, Dredge clot retrieval stroke has a lower risk of complications and shorter recovery time than traditional surgical treatment.
Features &Advantages
1. Double layer stent, the double-layer movable mesh. Unlike previous devices with only a single-layer stent, Dredger clot retrieval stroke’s double-layer stent increases the success rate of thrombus removal and makes it easier to remove the thrombus during the operation. For those more stubborn and difficult-to-handle thrombi, the success rate of thrombus removal is higher than other similar devices.
2. Clot retrieval stroke is the thrombectomy device with the smallest radial support force, which is 15% lower than other similar devices. This means that the device will cause less damage to the intima of the blood vessel and produce less irritation during the thrombectomy process.
3. The front-end umbrella-style basket design. Clot retrieval stroke's mesh basket design has a pocket function, which prevents small particles of emboli from escaping distally during retrieval. This is a very important safety feature, as emboli would cause greater harm and risk if they escaped deeper. This design improvement can make the patient safer during thrombectomy.Design of protective umbrella net basket at remote part of stent.
4. The design of noninvasive guidewire tip can prevent the device from damaging the inner wall of the blood vessel during thrombectomy. Due to the characteristics of the non-invasive guide wire tip, the operator's operation becomes easier and safer. This feature fundamentally prevents damage to patients caused by improper operation.
5. Complete visible provides real-time visual feedback to assist clinicians during surgery.