Glutton Neuro Aspiration Catheter is used to remove the thrombus blocked in the large intracranial artery within 8 hours after the onset of ischemic stroke to restore blood flow, including internal carotid artery, M1 and M2 segments of middle cerebral artery, A1 and A2 segments of anterior cerebral artery.
GluttonTM Neuro Aspiration Catheter is a medical device used in the treatment of acute ischemic stroke. It is a thin, flexible catheter that is inserted into blood vessels in the brain to remove blood clots that are blocking blood flow. The device is specifically designed for patients who are experiencing an acute ischemic stroke, which is a type of stroke caused by a blood clot that restricts blood flow to the brain. This type of stroke is a medical emergency and requires immediate treatment to minimize the risk of brain damage or death. The catheter is particularly effective in treating larger blood clots that cannot be dissolved with medication alone. The catheter is inserted into the blocked blood vessel through a small incision in the groin or arm and guided to the site of the clot in the brain. Once in place, the catheter uses suction to remove the clot and restore blood flow to the affected area.
Product Characteristics
1. The neuro aspiration catheter body is coated with hydrophilic coating.
The hydrophilic coating is specifically designed to reduce the friction between the catheter and the walls of the blood vessels, which helps to minimize any damage or trauma caused to the surrounding tissue. This reduction in friction also makes it easier for the catheter to be moved through the vessels, which reduces the resistance encountered during insertion and removal.
2. Hybrid structure of coil and brading.
It enhances the tensile strength of the device. As it ensures the catheter can withstand the stresses of use without becoming damaged or breaking.
3. Proximal composite polymer enhances pushability.
It enhances the catheter's navigability, allowing physicians to move it through intricate angles and small openings smoothly.
4. 0.072 inch larger inner diameter
A 0.072 inch larger inner diameter can improve the suction efficiency of the device and capture large clots.
5. Distal multi-segment design of gradual hardness
It allows the catheter to navigate through complex vascular structures with ease, reducing the risk of damage to the blood vessels or surrounding tissues.
Product Superiority
1. The catheter body is coated with hydrophilic coating to reduce the push resistance and enhance the position.
2. 0.072 inch large inner lumen diameter provides greater efficiency during aspiration procedures to reduce the overall time of the procedure and the risk of complications.
3. Excellent navigability is easily to navigate to the M1 and M2 segment.