The GluttonTM Access Aspiration Catheter features a big lumen and superior pushability and flexibility designed for removing thrombus effectively and rapidly in patients with acute ischemic stroke secondary to intracranial large vessel occlusion
The GluttonTM Access Aspiration Catheter is designed to access targeted vessels easily, restore cerebral blood flow quickly, and retrieve clots in patients experiencing acute ischaemic stroke. It is widely used in mechanical thrombectomy for acute ischemic stroke due to large vessel occlusion.
GluttonTM Access Aspiration Catheter is a thin, flexible tube that is inserted into the blood vessel in order to remove the clot. The device is designed to be used in minimally invasive procedures, such as angioplasty and stenting, where a small incision is made in the skin and the catheter is threaded through the blood vessel to reach the site of the clot. The catheter is typically made of medical-grade plastic or metal and features a variety of different components. At the tip of the catheter is a small, hollow tube called a lumen. This lumen is used to suction the clot out of the body. The catheter also features a pusher wire, which is used to help guide the catheter through the blood vessel.The design of the Thrombus Aspiration Catheter is optimized to provide maximum blood flow and suction. The catheter is carefully engineered to be flexible and easy to maneuver through the blood vessel, even around tight corners and bends. This flexibility is key to ensuring that the catheter can reach the site of the clot and effectively remove it. One important aspect of the thrombus aspiration catheter is the size and hardness of the lumen. The size and hardness of the lumen can have a significant impact on the device's ability to remove the clot. A larger, harder lumen will provide more suction and may be more effective in removing the clot.
Features&Benefits
1. Structure of coil and braid provides flexibility and allows freer manipulation.
2. The 0.072" large diameter lumen allows for a higher rate of aspiration and increased aspiration volumes.
3. Multiple segments of high-performance is designed to provide optimal flexibility and trackability to the distal tip.
4. Proximal composite polymer improves pushability and reduces the chances of derformation.
5. It is compatible with 6F long sheath.
6. Hydrophilic coating on the distal segment allows for smooth delivery to target site.
7. Access Aspiration Catheter has a lubricious coating at the distal end to reduce friction during use.