Resvent Automatic BPAP Machine
Automatic BPAP Machine
Multiple modes cater to different needs with auto settings for quick start,Benefit from the Intelligent Pressure Release (IPR) with three customizable modes.
BPAP
Intelligently adapt to user needs, automatically adjust the pressure to eusure you get a better sleep.
iBreeze Automatic BPAP Machine
-Treatment Modes
CPAP,APAP, S, Auto S,S/T, Auto S/T,T,PC
-Pressure Range
4-25cmH2O/4-30cmH2O
-Ramp
0-60min
-Weight
Approximately 1.60 kg
-Static Pressure Range
±0.5 cm H20
-Humidification
1-8Level, Auto
-Humidification in safe
Anti dry heating
-Data Management
SD card storage of 365 days, Automatic data upload to the cloud through WiFi connection
Important
Read this entire guide before using the device.
1.Model
¡Breeze 25STA、iBreeze 30STA
2.Intended Use
The iBreeze BPAP systems is intended to provide ventilation fornon-dependent, spontaneously breathing adult (30kg and above) with respiratory insufficiency, or respiratory failure, with or without Obstructive Sleep Apnea (OSA) and Chronic Obstructive Pulmonary Diseases (COPD), it is for use in the home, hospital, or institutional environment.
3.Contraindications
When assessing the relative risks and benefits of using this equipment, the clinician should understand that this device can deliver pressures up to 30 cmH2O. In the event of certain fault conditions, maximum pressure 40 cmH20 is possible. Studies have shown that the following pre-existing conditions may contraindicate the use of BPAP therapy for some patients:
Severe coronary artery disease
Bullous Lung Disease
Pathologically Low Blood Pressure
Bypassed Upper Airway
Pneumothorax
Caution should be used when prescribing BPAP therapy for susceptible patients such as
those with: cerebral spinal fluid (CSF) leaks, abnormalities of the cribriform plate, prior history of head trauma, and/or Pneumothorax.
The use of positive airwaypressure therapy may be temporarily contraindicated if you exhibit signs of a sinusor middle ear.
Note:In either case above, it can only be determined by a competentphysician whether to use the device.
4.User qualifications
The person operating the device by the instruction in the user's manual is referred as the "user". In contrast, a "patient" is the person receiving the therapy. Always perform all the operating steps in accordance with the user's manual Some lay person can receive specified professional training about how to use the device including all related to accessories from your dealer or the manufacturer.
Fresh Breath
Built-in humidifier to avoid dry breathing Feel fresh like being in a rainforest
Comprehensive humidity solution
-Automatic detection of ambient temperature and humidity
-8 levels of humidity
-Anti dry heating
-Anti-backflow